PVC _ Natural (Grade: PVC E)

Unit

Test Method

Result

Item

g/

ASTM D792

1.4±0.02

Density

N/

IEC 60811-1-1

15±0.5

Ultimate Tensile Strength

%

IEC 60811-1-1

400±50

Elongation At Break

Shore A

ASTM D2240

83±3

Hardness

Minutes

IEC 60811-3-2

350±20

Heat Stability

  

Application
Insulating wires for fixed installation with nominal voltage 450-750in90°C
Insulating flexible power cables and wires with nominal voltage 300-500in90°C

 

 